Using different physical methods for demining plastic mines,detection explosives in customs Group Manager: landmines-owner@egroups.com To subscribe, send a...
Dr.A.Hibbs from QM in USA had given the information ,that they can detect 30g RDX and 450g TNT in 2 s scan at 5 cm from flat surface coil.The NQR-detector for ...
4
Grechishkin
grechishkin@...
Mar 10, 1999 7:03 pm
... ïÔ: ëÏÍÕ: landmines@egroups.com ôÅÍÁ: Graund Penetrating Radar äÁÔÁ: 3 ÍÁÒÔÁ 1999 Ç. 23:26 GPR works by emitting into the...
5
Andy Hibbs
ANDY@...
Mar 10, 1999 7:03 pm
Two factors which are also relevent in mine detection are the coil size and the power used. In our tests we are now using a hand carried coil which weighs...
6
Grechishkin
grechishkin@...
Mar 10, 1999 8:06 pm
For 90-pulse in 14N NQR in explosives H1=37 G (RDX) and H1=3*10(-4)*(PQ/vV)(1/2), where P-output power of the transmitter in watts,Q-quality factor of the ...
7
Grechishkin
grechishkin@...
Mar 14, 1999 2:47 pm
In RDX at the frequency 5192 kHz at room temperature the relaxation time T2=1.3 ms, asimetry parameter z=0.638 and H1=37 G,for TNT H1=29 G at 888 kHz,z=0.29. ...
8
Grechishkin
grechishkin@...
Mar 15, 1999 7:10 am
In 1980,p.71-113,Advances of NQR,edited by J.A.S.Smith we discribed the two-freguency pulse equipment NQR ,which we used in 1975 for first detection NQR in ...
9
Grechishkin
grechishkin@...
Mar 15, 1999 6:46 pm
In documents of FAA there is the discussion of CTX-5000 and NQR.We worked in NQR control more that 20 years and can say ,that now only hand bags control by NQR...
10
Grechishkin
grechishkin@...
Mar 16, 1999 4:38 am
FAA- certified CTX-5000SP EDS with price 1 million$ in operation in Europe and Israel gives 30 to 50% of all checked bags false alarms.In principal x-ray can...
11
Grechishkin
grechishkin@...
Mar 16, 1999 4:10 am
Dr.Hibbs had given the information ,that they were working with H1=1 G.In this case duration of 90-pulse may be 500 microseconds.In 110 litres coil we used ...
12
Grechishkin
grechishkin@...
Mar 16, 1999 2:29 pm
The NQR line width was very low ,about 200Hz and H1=1 G is possible to use with duration of pulse 500 microseconds and top-power 0.5 kW in 100 litres coil. But...
13
Grechishkin
grechishkin@...
Mar 16, 1999 4:30 pm
t-is the time of accomulation,than t=(nz2vV)/(8j2dQP1*9*10(-8)),where n-number of accomulation,z-number pi,v-NQR frequency,V-volume of coil,j-giromagnetic ...
14
Grechishkin
grechishkin@...
Mar 17, 1999 3:41 pm
In 1978-1983 in KSU were made the reports with NQR-technology for mine-detection,post and aviation hand bags control: Number of State registration ...
15
Grechishkin
grechishkin@...
Mar 18, 1999 6:50 pm
In Russia we made a similar testing in 1984 ( Izvestija Vuzov,7,58-61,1992) but in our testing the filling fector was much higher.We tested flat surface coils ...
16
Grechishkin
grechishkin@...
Mar 19, 1999 4:21 am
The last testing in QM (USA) give nothing new and only are repeting the old testing in Kaliningrad and Novosibirsk.In Russia after the collapse of SU this ...
17
Grechishkin
grechishkin@...
Mar 21, 1999 5:30 pm
We think that John Denker is wrong in some parts of his critik NQR. ... eGroup home: http://www.eGroups.com/list/landmines Free Web-based e-mail groups by...
18
Grechishkin
grechishkin@...
Mar 25, 1999 9:19 am
Dear Zou Nan! I send you our last tecting in Cina and Australia. rgds VSG ... Grechishkin <grechishkin@...> NQR -landmines detector NQR pulse...
19
Grechishkin
grechishkin@...
Mar 25, 1999 4:02 pm
It is well known,that in cross-coils method by Felix Bloch the filling factor is calculated for receiver coil not for exiting.We described the optimal coil for...
20
Grechishkin
grechishkin@...
Mar 29, 1999 12:14 pm
In author certificate N265282,1.12.1987 ( Grechishkin V.S.,Rudakov T.N. et al.) we patenred 4 channel NQR device for mine detection in the area.NQR signals ...
21
Grechishkin
grechishkin@...
Mar 31, 1999 6:25 pm
... Îò: Franz Fujara <fujara@...> Êîìó: Grechishkin <grechishkin@...> Òåìà: Kosovo Äàòà: 31 ìàðòà 1999 ã....
22
Grechishkin
grechishkin@...
Apr 5, 1999 4:22 pm
We started our work in NQR-technology in 1971 and worked with 10 customers. 11 years there was the work with Institute of Applite Physics in Novosibirsk,6...
23
Grechishkin
grechishkin@...
Apr 6, 1999 3:11 pm
... ïÔ: Grechishkin <grechishkin@...> ëÏÍÕ: mines@egroups.com ôÅÍÁ: Future of NQR äÁÔÁ: 6 ÁÐÒÅÌÑ 1999 Ç. 18:07 The applications...
24
Grechishkin
grechishkin@...
Apr 7, 1999 9:05 pm
InVision made more than 100 devicies CTX-5000 for computer tomography x-ray and sold in 24 countries with the price 1 million $ for detection of ...
25
Grechishkin
grechishkin@...
Apr 11, 1999 4:44 pm
We are more optimistic about NQR mine detection than we were a few years ago. It is demonstrated that detection of even reasonably small quantities of TNT is...
26
Grechishkin
grechishkin@...
Apr 11, 1999 8:33 pm
... Îò: Susan Cagle <SUSAN@...> Êîìó: grechishkin@... Òåìà: Papers from Dr. Hibbs Äàòà: 17 ìàðòà 1999 ã. 19:52 Dr....
... Îò: James Colton <jcolton@...> Êîìó: Grechishkin <grechishkin@...> Òåìà: RE: [analysisexplosives] Fw: minimal mass Äàòà:...
29
Grechishkin
grechishkin@...
Apr 13, 1999 7:53 pm
In stochastic exitation the rf power is decreased by a factor of 1000 compared to pulsed exitation,the deadtime can be reduced.But in NQR it is impossible to...
30
Grechishkin
grechishkin@...
Apr 15, 1999 6:16 pm
In Uspekhi Fiz.Nauk,69,189-216,1959 we described stochstic NQR detector with very low power.This principal one may use for T1 about 1 s like in TNT.But in this...